Non-Intrusive Load Monitoring of HVAC Components using Signal Unmixing

Load disaggregation-Alireza Rahimpour-Global SIP 2015
Abstract: 

Heating, Ventilating and Air Conditioning units (HVAC) are a major electrical energy consumer in buildings. Monitoring of the operation and energy consumption of HVAC would increase the awareness of building owners and maintenance service providers of the condition and quality of performance of these units, enabling conditioned-based maintenance which would help achieving high efficiency in energy consumption. In this paper, a novel non-intrusive method based on constrained non-negative matrix factorization is proposed for monitoring the different components of HVAC unit by only having access to the whole building aggregated power signal. At the first level of this hierarchical approach, power consumption of the building is decomposed to energy consumption of the HVAC unit and all the other electrical devices operating in the building such as lighting and plug loads. Then, the estimated power signal of the HVAC is used to estimate the power consumption profile of the HVAC major electrical loads such as compressors, condenser fans and indoor blower. Experiments conducted on
real data collected from a building testbed maintained at the Oak Ridge National Laboratory (ORNL) demonstrate high accuracy on disaggregation task.

up
0 users have voted:

Paper Details

Authors:
Hairong Qi, David Fugatey, Teja Kuruganti
Submitted On:
23 February 2016 - 1:44pm
Short Link:
Type:
Presentation Slides
Event:
Presenter's Name:
Alireza Rahimpour
Document Year:
2015
Cite

Document Files

GSIP2015-ALIREZA RAHIMPOUR.pdf

(95)

Subscribe

[1] Hairong Qi, David Fugatey, Teja Kuruganti, "Non-Intrusive Load Monitoring of HVAC Components using Signal Unmixing", IEEE SigPort, 2015. [Online]. Available: http://sigport.org/504. Accessed: Jul. 13, 2020.
@article{504-15,
url = {http://sigport.org/504},
author = {Hairong Qi; David Fugatey; Teja Kuruganti },
publisher = {IEEE SigPort},
title = {Non-Intrusive Load Monitoring of HVAC Components using Signal Unmixing},
year = {2015} }
TY - EJOUR
T1 - Non-Intrusive Load Monitoring of HVAC Components using Signal Unmixing
AU - Hairong Qi; David Fugatey; Teja Kuruganti
PY - 2015
PB - IEEE SigPort
UR - http://sigport.org/504
ER -
Hairong Qi, David Fugatey, Teja Kuruganti. (2015). Non-Intrusive Load Monitoring of HVAC Components using Signal Unmixing. IEEE SigPort. http://sigport.org/504
Hairong Qi, David Fugatey, Teja Kuruganti, 2015. Non-Intrusive Load Monitoring of HVAC Components using Signal Unmixing. Available at: http://sigport.org/504.
Hairong Qi, David Fugatey, Teja Kuruganti. (2015). "Non-Intrusive Load Monitoring of HVAC Components using Signal Unmixing." Web.
1. Hairong Qi, David Fugatey, Teja Kuruganti. Non-Intrusive Load Monitoring of HVAC Components using Signal Unmixing [Internet]. IEEE SigPort; 2015. Available from : http://sigport.org/504